Baxter pump locking instructions. SIGMA SPECTRUM INFUSION PUMP WITH MASTER DRUG LIBRARY.


  1. Baxter pump locking instructions. • Hold tubing down on top of the pump while removing the blue slide clamp. VOLUMETRIC INFUSION PUMP. Bringing together the Novum IQ Large Volume Pump, the Novum IQ Syringe Pump, the IQ Enterprise Connectivity Suite and Dose IQ Safety Software, the Novum IQ Infusion Platform is transforming infusion delivery. pdf Recall Letter Sigma spectrum Check battery. Infusion Pump. Also for: Homechoice pro. %PDF-1. This is accomplished by pulling the tab straight out from the Battery Pack mounting cavity. The Spectrum IQ system also uses Baxter’s Single Set Technology. This operator's manual provides instructions on how to use the SIGMA Spectrum infusion pump, including setup, operation, alarms, and maintenance. Alarm Volume and Tone Variable, three levels: high, medium, low View and Download Baxter Healthcare Corporation PCA II service manual online. View and Download baxter 35700BAX preventive maintenance online. View and Download baxter 2M91617A operator's manual online. As one of the more commonly used infusion pumps, the Baxter Sigma Spectrum is a small and lightweight smart pump that can be used in a variety of healthcare settings. Refer to the SIGMA Spectrum Infusion System Service Manual (P/N 41019v0800) or contact Baxter Technical Support for Pump service needs; including circuit diagrams, component part lists, descriptions, calibration instructions, or other information. The pump uses state of the art microprocessor electronics for control of all functions, Car- tridges, available separately, allow the pump operator to change the characteristics of the pump The Auto Syringe AS50 Infusion Pump Operator’s Manual is intended for use by trained healthcare professionals familiar with infusions and infusion pump procedures. Sterile Package (1/Pack 10/Case) Configuration Manual If you need to connect the pump to an electrical power source, you will also need a Baxter AC adapter, which is sold separately. View and Download baxter Ipump operator's manual online. The Repeater Pump is a versatile peristaltic pump which plays an important role in routine pharmacy procedures - delivering accuracy and multi-speed settings for fluid transfer processes the way you need them. View and Download Sigma Spectrum 35700ABB service manual online. ) View and Download baxter Colleague 3 operator's manual online. Two separate pump channels which allow the Flo-Gard® 6300 device to do the work of two conventional Use only with standard Baxter soft tubing admini-stration sets with an “s” designation. Dual Channel Volumetric Infusion Pump. Locking (squeeze-release): Locking connectors use a latching mechanism to prevent accidental disconnection during assembly and use. Baxter Spectrum IQ Operators Manual View and Download baxter PCA II operator's manual online. Maximum Allowable Pressure while in Downstream Occlusion 310 kPA (45 psi) Are you maximizing the value of your REPEATER Pump? Are you maximizing the value of your REPEATER Pump? The Baxter REPEATER Pump is a peristaltic pump designed exclusively for pharmacy applications. Products affected: Licence name: Novum IQ Large Volume Pump Device Identifier: 40700BAX Medical Device Licence Number: 104574 Market Authorization Holder: Baxter Corporation Key messages: Since 2021, various safety risks associated with Baxter’s Novum IQ Large Volume Pump (LVP) have been identified and communicated by Baxter to users. 1 A dimmed flow rate display indicates the associated pump is not rotating, for example, following a bag change as scales stabilize, or an alarm that stops fluid pumps. Volumetric Infusion pump. Use to transfer sterile fluids from one container to another using a REPEATER Pump. Intended Device Use The Spectrum Infusion Pump with Master Drug Library is intended to be used for the controlled administration of intravenous fluids. Pain Management System. Flo-Gard 6201 water pump pdf manual download. The pump can be used with or without a primary IV delivery system. Read and understand this manual before using the Flo-Gard® 6201 pump. The Baxter non-DEHP administration sets should not be used with the SIGMA Spectrum Pump for medications and therapies requiring infusion flow rates and durations outside of ranges specified above. INSTRUCTIONS FOR Step 5. 2 MICRON FILTER CLEARLINK SYSTEM, VENTED PACLITAXEL SET (10 DROPS/ML), POLYETHYLENE LINED TUBING, NON-DEHP PUMP SEGMENT, 0. View and Download Sigma Spectrum quick reference manual online. PCA II water pump pdf manual download. The battery tab has been provided to isolate the battery voltage from the pump during transport and distribution. Flo-Gard 6301 water pump pdf manual download. sigmaspectrum 35700ABB water pump pdf manual download. Using a formula provided electronically or entered manually, the compounder withdraws a specified volume of each ingredient from its source container in a specified sequence, and pumps each ingredient into a patient bag Provide strain relief when removing the blue slide clamp from the pump. pdf We recently created a new training video to take a closer look at the different features of the Sigma pump, how to use the pump, and a few tricks and tips that will help healthcare workers and educators be able to use this Baxter IV pump effectively. ISN’T JUST A PUMP It’s an integrated, intelligent ecosystem designed to support complex infusion practices for your patients. Jun 7, 2025 · On June 6, 2025, the U. Disclaimer View and Download Sigma Sigmaspectrum 35700ABB operator's manual online. View and Download baxter Flo-Gard 6201 operator's manual online. Feb 24, 2025 · Email | Print SKU: H938331 REPEATER Pump Tube Set. Similar screens are used during setup. Using the Sigma Spectrum Infusion Pump Expanded Scope Protocol for Interfacility Transfer Intravenous Infusion Pump Use During Interfacility Transfers Compatible Baxter IV Sets (US) (For use with SIGMA Spectrum and Spectrum IQ Infusion Pumps that have been calibrated for Baxter IV set tubing). Jan 1, 2025 · Email | Print SKU: 40800BAXUS Novum IQ Syringe Pump (includes pump, battery and power cord). It is used during the compounding process. Baxter Spectrum IQ Installation and Maintenance Manual Apr 25, 2025 · The Baxter Spectrum IQ Service Manual is a comprehensive guide ensuring optimal pump performance, safety, and compliance, while providing detailed maintenance and repair procedures for healthcare professionals. The information on this page is intended to provide a The Luer Lock Connector (refer to Diagram 1) should always be taped to your skin at approximately the same level as the top of the device (ie. The Novum IQ syringe pump is intended to deliver an infusion through the following clinically accepted routes of administration: intravenous, arterial, enteral and subcutaneous. Remove the battery insulating tab prior to charging the pump’s battery or operating the pump. Driven by digital innovation, Baxter's integrated platform approach is designed to streamline infusion administration and save time, reinforce infusion safety and enable the continuous This manual and any information contained within, may not be reproduced, distributed, or transmitted in any form, or by any means, for any purpose, without the express written permission of Baxter. Feb 24, 2025 · Male Luer Lock connections allow needle, luer lock spike or dispensing pin to be used at the inlet and outlet. The Novum IQ syringe pump is intended to be used for the controlled administration of fluids. Step 6. Compatible Baxter IV Sets (For use with SIGMA Spectrum and Spectrum IQ Infusion Pumps that have been calibrated for Baxter IV set tubing). Baxter brings an award-winning heritage of experience to deliver market-leading infusion systems innovation. Colleague CXE water pump pdf manual download. (See “Accessories, Disposables, and Recommended Sets,” 8-1. Vented Inlet Spike and Male Luer Lock Outlet. Designed to allow clinicians to easily switch from gravity and pump applications without For the purposes of this professional guide, all instructions and guidelines for the Infusor also apply to the Small Volume Infusor (Folfusor). Mar 17, 2015 · Press and hold the “Panel Lock Out” button then turn to the front side of the pump 4. Volumetric Infusion Pump. 35700BAX water pump pdf manual download. Warning There are risks associated with using anything other than the recommended sets with this device. Pull the battery tab straight out from the Battery Pack cavity. Once removed, the slide clamp should be open and move freely along the tubing before starting an infusion. Spectrum IQ Infusion Pump is Rx only. Each eLearning module provides details on key functions and use scenarios for both the SIGMA Spectrum Infusion pump and MDL. Auto Syringe AS50 water pump pdf manual download. The latch is located on one end of a tab so it may flex and lock into place when coupled with its matching connector. 2 ml (±10%) and relieve pharmacy technicians of repetitive manual tasks. Recyclable Battery Pack- Dispose of Properly. Building on the Spectrum platform’s industry-leading drug library compliance and ease of use, Spectrum IQ Infusion System fully integrates with your EMR, adding another layer of safety to your infusion and providing immediate and measurable results to health systems and the patients they serve. Medical Equipment, Oven user manuals, operating guides & specifications View and Download baxter Flo-Gard 6201 service manual online. Also for: 2m91637a. Configuration Manual If you need to connect the pump to an electrical power source, you will also need a Baxter AC adapter, which is sold separately. Also for: Sigmaspectrum 35700bax. The FDA has identified it as a class I recall, the most serious type, where use of the View and Download Baxter Colleague instruction manual online. These fluids may include pharmaceutical drugs, blood, blood products, and mixtures of required patient therapy. View and Download baxter Auto Syringe AS50 operator's manual online. Information on devices serviced by Baxter. NOTE: The superscript numbers referenced in the Compatible IV Set List correspond with the numbers listed in the associated warning. Luer Lock-Luer Lock, Male Luer Lock Connections allow needle, Luer Lock Spike or Dispensing Pin to be used at the inlet and outlet H93821 REPEATER Pump Tube Set. Luer Lock-Luer Lock, Low Volume Priming, External Thread. y filters which are suit-able for use with infusion pu Baxter SIGMA Spectrum Manuals / Documents Approved Cleaning Agents. The Auto Syringe AS50 Infusion Pump Operator’s Manual is intended for use by trained healthcare professionals familiar with infusions and infusion pump procedures. spectrum 35700ABB laboratory equipment pdf manual download. In this video, we take a INDICATIONS FOR USE — NOVUM IQ LARGE VOLUME PUMP (LVP) The Novum IQ LVP is intended for use on adults and pediatric subpopulations, except for neonates, for the controlled administration of fluids, pharmaceutical drugs, parenteral nutrition, blood and blood products through the following clinically accepted routes of administration Pump Guide This guide reviews Baxter Pump and IV Tubings & Filters, PCA/PCEA, and Syringe Pumps. pdf), Text File (. The Novum IQ Battery (Very) Low – Send Pump For Repair–ThisalertappearsduringaLowBattery alarmwhen,throughatutorial7basedsystemofuser prompts,ithasbeendeterminedthat theexternalpowercordorsupplyisdamagedandma yneedtobeservicedorreplaced. HomeChoice medical equipment pdf manual download. Library of the latest service related documents. txt) or read online for free. The intended routes of administration consist of the following clinically acceptable routes: intravenous, arterial, subcutaneous View and Download baxter Flo-Gard 6301 operator's manual online. If display abnormalities are observed, discontinue use of the pump and refer servicing to qualified service personnel at your facility or return the pump to Baxter for service. Up to date Spare Parts and Service tool listings and Online ordering. For the safe and proper use of the devices referenced here, refer to the complete Instructions for Use or the appropriate operator’s manual. Flo-Gard 6201 medical equipment pdf manual download. 05 Operator Manual Today we look at the operation and programing of the Baxter IV pump for use at Valley Community Hospital. 2M91617A medical equipment pdf manual download. 4 days ago · The exclusive Baxter technologies built into the Spectrum IQ system help achieve measurable results by covering the entire medication process: from finding an infusion pump with Tagless Asset Tracking, to automating infusion analytics. Food and Drug Administration (FDA) shared Baxter’s recall that it is updating its usage instructions for the Novum IQ large-volume pump (LVP). Fill Port Cap - refer to Diagram 1) of the Infusor/Intermate in order to maintain an accurate flow rate. To complement the various REPEATER Pump functions, Baxter provides a wide range of accessories that aid in pharmacy fluid transfer. Oct 8, 2023 · Today, we will discuss all of the steps necessary to properly secure your Baxter Infusion System. This Patient Guide will help you use your Infusor System safely. spectrum laboratory equipment pdf manual download. Downloadable PDF Manual for Sigma Spectrum V 6. On the front keypad, locate the “Stop” and “On/Off” buttons. Prior to using this pump, read this manual carefully to fully understand the pump’s functionality and to ensure safe and proper operation. Spectrum IQ Infusion Pump - For the safe and proper use of the devices referenced here within, refer to the complete Instructions for Use or the appropriate operator’s manual. Pump Screen The pump screen shows a diagram of the valve set. Also for: 2m8151, 2m8151k. Baxter’s Infusor System has been prescribed for your home infusion therapy and is designed to deliver drugs over a specific time period. Luer Lock-Luer Lock, Low Volume Priming, External Thread H938331 REPEATER Pump Tube Set. The Novum IQ syringe pump is intended to be used in conjunction with legally marketed and compatible administration sets, syringes and medications provided by the user. Our Spectrum IQ Infusion System revolutionizes the traditional idea of an integrated smart pump. By learning how to lock and protect your pump from unwanted tampering, you can rest easy knowing that medications have been safely delivered in the correct manner. The elastomeric technology promotes patient recovery and improves patient quality of life by The Baxter single set can be used both as gravity and in the Sigma Spectrum Infusion pump throughout multiple care areas. Also for: 2l3107, 2l3107k. The Luer Lock Connector (refer to Diagram 1) should always be taped to your skin at approximately the same level as the top of the device (ie. S. However, the screen always includes these elements: Alarm Volume and Tone Variable, three levels: high, medium, low Servicing the Spectrum IQ infusion pump is restricted to qualified, Baxter trained, service personnel who employ Baxter authorized parts and procedures. The Novum IQ Syringe Pump helps protect even the smallest and most vulnerable patients and supports standardized infusion administration. Also for: Spectrum 35700bax. Delivering innovations that enable reduced operating times, faster patient recovery and improved outcomes. Feb 24, 2025 · Email | Print SKU: H93811 REPEATER Pump Tube Set, Universal Spike-Luer Lock. When infusing fluid through a central line catheter, Baxter recommends that sets with a Luer lock adapter be used. Push the pump back against the mount and then push the locking plate up to lock the pump into place. Colleague 3 medical equipment pdf manual download. These include pharmaceutical drugs, parenteral nutrition, blood and blood products, and enteral nutrition. Baxter is one of the world's leading manufacturers of commercially prepared IV solutions in flexible containers. Sterile Package (1/Pack 10/Case) With intuitive workflows, exclusive on-screen prompts to confirm IV infusion tasks, and line management technology, the Spectrum IQ system is designed to guide the user though the infusion programming process safely and efficiently. Baxter's Advanced Surgery business unit offers a comprehensive line of biologics, devices and combination products. ) Contact Baxter Technical Support for Pump service needs; including circuit diagrams, component part lists, descriptions, calibration instructions, or other information. Baxter offers a robust portfolio of eLearning modules to refresh your SIGMA Spectrum Infusion pump and master drug library (MDL) training when it is convenient for you. SIGMA SPECTRUM INFUSION PUMP WITH MASTER DRUG LIBRARY. Medication is delivered to the patient as the elastomeric “balloon” consistently deflates and gently pushes solution through the IV tubing and into the catheter/port. The Single Set Technology can reduce the number of set-ups and teardowns which can decrease the risk of touch contamination, and has shown up to 53% cost savings in IV tubing sets and up to 30% reduction in IV tubing usage. Our peristaltic Repeater Pharmacy Pump performs automated multi-speed fluid transfers that promote accuracy at volumes as low as 0. Ipump medical equipment pdf manual download. Global Service Manual Prior to servicing these pumps, read this manual and the pump’s Operator’s Manual carefully to fully understand the pump’s functionality and to ensure safe and proper servicing. View and Download baxter HomeChoice manual online. Mar 12, 2013 · They can be reached directly on (800) 356-3454 or through Baxter's legacy support line, 1-800-THE-PUMP Option 5. NOTE: Pump should not be serviced while in use on a patient. 2M916117;2M91637 VOLUMETRIC INFUSION PUMP. Spectrum_IQ_Installation_and_Maintenance_Manual-41019v0900 - Free download as PDF File (. The REPEATER Pump is a peristaltic pump for fluid transfer that facilitates repeatable drug dosage distribution and reconstitution in hospital pharmacies. The PCA II Pump is a syringe infusion pump capable of both continuous and intermittent infusion of parenteral fluids in a hospital setting. Spectrum_IQ_Operators_Manual-41018v0900 - Free download as PDF File (. These include anesthetic gases, or inhaled anesthetics, and anesthesia-related critical care drugs. Refer to the SIGMA Spectrum Infusion System Service Manual (P/N 41019v0800) or contact Baxter Technical Support for Pump service needs; including circuit diagrams, component part lists, descriptions, calibration instructions, or other information. For more than 30 years, Baxter has been facilitating automated fluid transfers with the aim of improving accuracy and increasing the efficiency of pharmacy operations. Also for: Colleague 3 cxe. Additional Service Passwords can be provided to graduates of the SIGMA Spectrum service school. IT’S ADVANCED TECHNOLOGY TO ENHANCE SAFETY AND EASE OF USE As part of the fully integrated Novum IQ Infusion Platform, the Novum IQ Large Volume Pump is designed to protect infusions for all patients and elevate the infusion therapy experience for clinicians. Universal Spike-Luer Lock. Use only with standard Baxter soft tubing admini-stration sets with an “s” designation. The FDA said that the recall involves updating instructions for using the devices, not removing them from where they are used or sold. y filters which are suit-able for use with infusion pu H93862 REPEATER Pump Tube Set. INJECTION SITE, MALE LUER LOCK ADAPTER INTERLINK SYSTEM, PACLITAXEL SET, POLYETHYLENE LINED TUBING, NON-DEHP PUMP SEGMENT, 0. Vented Spike and Male Luer Lock Refer to the SIGMA Spectrum Infusion System Service Manual (P/N 41019v0800) or contact Baxter Technical Support for Pump service needs; including circuit diagrams, component part lists, descriptions, calibration instructions, or other information. To order additional copies of this manual, or other related manuals, contact your local Baxter Service Center. . The device is for use with IV bags, syringes, elastomeric infusers and other drug administration containers. Clinicians may continue to use Spectrum V8 and Spectrum IQ infusion pumps by following on-screen instructions, infusion setup instructions in the Preparing the Pump and IV Sets and Programming the Pump sections, and upstream occlusion alarm troubleshooting in the Alarms section of the Operator’s Manual. Use of other parts and servicing procedures is prohibited. 2 MICRON FILTER, LUER ACTIVATED VALVE, MALE LUER LOCK ADAPTER View & download of more than 255 baxter PDF user manuals, service manuals, operating guides. The device's features in-clude: Aug 6, 2015 · Refer to the SIGMA Spectrum Infusion System Service Manual (P/N 41019v0800) or contact Baxter Technical Support for Pump service needs; including circuit diagrams, component part lists, descriptions, calibration instructions, or other information. Introduction The Flo-Gard® 6301 Dual Channel Volumetric Infusion Pump from Baxter can deliver a wide variety of fluids over a broad range of infusion rates. If you have a Baxter 6201 or Baxter 6301 with an error code F49 or F94, you can usually reset that error code quickly and easily with the process detailed on pages 5 & 6 of this document - so you won’t have to send in your pump! View online or download Baxter 35700BAX2 Infusion Pump Operator's Manual. View and Download baxter Colleague CXE operator's manual online. Uses standard Baxter solution administration sets. The Novum IQ syringe pump is intended to deliver an infusion through the following clinically accepted routes of administration: intravenous, arterial, enteral, and subcutaneous. We would like to show you a description here but the site won’t allow us. 5 %âãÏÓ 6480 0 obj > endobj 6504 0 obj >/Filter/FlateDecode/ID[7017B660C5200D4EAC2270E94050B244>20B37AAE3EC24F0F86EAB42ECB4933F9>]/Index[6480 42]/Info 6479 INTRODUCTION The Baxter ExactaMix® 1200 Compounder is an automated pumping system that compounds multiple sterile ingredients into a finished solution in a single patient bag. To close/ release the lid pull the white tab on the inside upper left corner. Pump screen at the start of the compounding process The appearance of the pump screen changes slightly during various steps of the compounding process. Portfolio Overview: Baxter Elastomeric Pumps are non-electronic medication pumps designed to provide ambulatory infusion therapy. tnc t6111 vu nknr0ha vycn 4dk ncgfrx uw wtj 5ysv